https://repositorio.ufjf.br/jspui/handle/ufjf/12891
File | Description | Size | Format | |
---|---|---|---|---|
guilhermedeoliveiraalves.pdf | 2.82 MB | Adobe PDF | View/Open |
Type: | Tese |
Title: | Inclusão do modelo do regulador de velocidade nos problemas de fluxo de potência e fluxo de potência ótimo com abordagem trifásica |
Author: | Alves, Guilherme de Oliveira |
First Advisor: | Passos Filho, João Alberto |
Referee Member: | Rodrigues, Anselmo Barbosa |
Referee Member: | Silva Junior, Ivo Chaves da |
Referee Member: | Melo, Igor Delgado de |
Referee Member: | London Junior, Joao Bosco Augusto |
Referee Member: | Oliveira, Leonardo Willer de |
Resumo: | Neste trabalho são desenvolvidas formulações alternativas dos problemas de fluxo de potência e fluxo de potência ótimo utilizando as modelagens de sequência positiva e trifásica desequilibrada, considerando a representação do regulador de velocidade dos geradores síncronos (GSs) em regime permanente. A regulação de tensão e frequência das unidades de geração distribuída (GD) usando inversores também são incluídas nas modelagens trifásicas. No fluxo de potência, um novo conceito de barra de referência é introduzido nas formulações desenvolvidas, permitindo que qualquer barra de carga ou geração seja a referência angular do sistema. As novas equações são incorporadas ao modelo de fluxo de potência, resultando em um sistema de equações aumentado. Este novo sistema de equações é resolvido usando o método de Newton-Raphson. O fluxo de potência proposto permite estimar o desvio de frequência devido a uma variação de carga e geração no sistema. Adicionalmente, as perdas ativas são distribuídas entre as unidades geradoras independente da escolha da barra de referência. As formulações propostas para o fluxo de potência ótimo consideram a representação do controle primário de frequência. A modelagem trifásica também inclui a representação dos controles das unidades GD. As formulações propostas podem determinar o corte de carga para manter a frequência do sistema dentro dos limites especificados. Os resultados obtidos pelas formulações de fluxo de potência são validados através dos programas ANAREDE e ANATEM, e de simulações em tempo real utilizando o RTDS, demonstrando a eficácia das formulações propostas. |
Abstract: | In this work, alternative formulations of the power flow and optimal power flow problems are developed using the positive sequence and unbalanced three-phase modeling, considering the steady-state synchronous generators (SGs) governor representation. Voltage and frequency regulation of distributed generation units (DG) using inverters are also included in the three-phase models. In the power flow, a new concept of a slack bus is introduced in the developed methodologies, allowing any load or generation bus to be the angular reference of the system. The new equations are incorporated into the power flow model, resulting in an augmented system of equations. This new system of equations is solved using the Newton-Raphson method. The proposed power flow allows estimating the frequency deviation due to a variation of system load and generation. Additionally, the active losses are distributed among the generation units regardless of the reference bus choice. The proposed optimal power flow formulations consider the representation of the primary frequency control. The three-phase modeling also includes the representation of the DG unit controls. The proposed formulations can determine the load shedding to maintain the system frequency within the specified limits. Results obtained by the power flow formulations are validated using ANAREDE, ANATEM programs, and real-time simulations using RTDS, demonstrating the effectiveness of the proposed formulations. |
Keywords: | Regulação primária de frequência Controle carga-frequência Controle de tensão e frequência em GDs Geração Distribuída Fluxo de potência desbalanceado trifásico Fluxo de potência Método de Injeção de Correntes Modelagem da barra de referência Análise de redes em regime permanente Primary frequency regulation Load-frequency control Voltage and frequency control in DGs Distributed Generation Three-phase unbalanced power flow Power flow Current Injection Method Reference bus modeling Steady-state network analysis |
CNPq: | CNPQ::ENGENHARIAS::ENGENHARIA DE MATERIAIS E METALURGICA |
Language: | por |
Country: | Brasil |
Publisher: | Universidade Federal de Juiz de Fora (UFJF) |
Institution Initials: | UFJF |
Department: | Faculdade de Engenharia |
Program: | Programa de Pós-graduação em Engenharia Elétrica |
Access Type: | Acesso Aberto |
DOI: | https://doi.org/10.34019/ufjf/te/2021/00018 |
URI: | https://repositorio.ufjf.br/jspui/handle/ufjf/12891 |
Issue Date: | 18-Mar-2021 |
Appears in Collections: | Doutorado em Engenharia Elétrica (Teses) |
Items in DSpace are protected by Creative Commons licenses, with all rights reserved, unless otherwise indicated.